Subjects · Leaving Cert Construction Studies
Leaving Cert Construction Studies: Airtightness & ventilation
How often Airtightness & ventilation comes up on the Construction Studies papers, every year it was asked, and questions to try.
HL Asked on 6 of the last 9 Higher Level papers, most recently in 2025. most years
OL Asked on 2 of the last 9 Ordinary Level papers, most recently in 2022.
June 2028 is the first exam on the new Construction Studies course. These come from the 2016–2025 papers, so read them as a guide.
Quick ones on Airtightness & ventilation.
- Burning a stove and watching the smoke
- Blower-door fan pressurisation at 50 Pa
- A thermal image only
- Moisture meter
- Laser level
- Smoke pencil
- Wet rooms: kitchen, bathrooms, utility
- The attic and the landing ceiling
- Bedrooms, living room and study
Show the answers
(a) Blower-door fan pressurisation at 50 Pa
(b) Smoke pencil
(c) Wet rooms: kitchen, bathrooms, utility
Higher Level
Asked on 6 of the last 9 Higher Level papers, most recently in 2025. most years
Every paper, year by year
| Year | Where it came up |
|---|---|
| 2025 | Q8 |
| 2024 | Q7 |
| 2023 | Q10a |
| 2022 | Q9 |
| 2021 | Not asked |
| 2019 | Not asked |
| 2018 | Q7 |
| 2017 | Q10a |
| 2016 | Not asked |
Links open the State Examinations Commission’s paper for that year.
More Airtightness & ventilation questions
Airtightness & ventilation, 2 marks
MVHR supplies fresh air to which rooms?
- Only the wet rooms: the kitchen and bathrooms
- Only the attic and the hot press
- Habitable rooms: bedrooms and living rooms
Show the answer
Habitable rooms: bedrooms and living rooms
Fresh, warmed air goes where people spend time and is extracted from kitchens and bathrooms, so air moves through the house from clean areas to moist ones.
Airtightness & ventilation, 3 marks
Units of air permeability measured in an airtightness test?
- kWh/m² per year
- m³/(h·m²) at 50 Pa
- W/m²K
Show the answer
m³/(h·m²) at 50 Pa
Air permeability is the leakage per hour per square metre of envelope at 50 Pa. The n50 figure instead divides the leakage by the house volume, giving air changes per hour.
Airtightness & ventilation, 3 marks
Why draw a continuous airtight line on the section drawings at design stage?
- So every junction's airtight detail is planned
- It marks the site boundary on the section
- It shows the route of the radon sump pipe
Show the answer
So every junction's airtight detail is planned
In the pencil test, if a pencil can trace the airtight layer round each section without lifting, the design is continuous. Gaps found on paper are cheap to fix.
Ordinary Level
Asked on 2 of the last 9 Ordinary Level papers, most recently in 2022.
Every paper, year by year
| Year | Where it came up |
|---|---|
| 2025 | Not asked |
| 2024 | Not asked |
| 2023 | Not asked |
| 2022 | Q8c |
| 2021 | Not asked |
| 2019 | Not asked |
| 2018 | Q8d |
| 2017 | Not asked |
| 2016 | Not asked |
Links open the State Examinations Commission’s paper for that year.
More Airtightness & ventilation questions
Airtightness & ventilation, 2 marks
What does airtightness mean in a house?
- Keeping every window and door shut all year round
- Removing all ventilation from the house
- Stopping uncontrolled air leaks through the building
Show the answer
Stopping uncontrolled air leaks through the building
Gaps round pipes, sockets and joints let warm air leak out. An airtight house stops these draughts, then ventilates in a controlled way.
Airtightness & ventilation, 2 marks
Test used to measure how airtight a house is?
- Slump test
- Blower door test
- Percolation test
Show the answer
Blower door test
A fan fitted in the front door pressurises the house. The air flow needed to hold the pressure shows how leaky it is, and leaks can then be found.
Airtightness & ventilation, 3 marks
Why does an airtight house need planned ventilation?
- To remove stale, moist air and bring in fresh air
- To keep the house much cooler during the winter months
- To let radon into the house from the ground
Show the answer
To remove stale, moist air and bring in fresh air
With draughts sealed, moisture and stale air from cooking, washing and breathing build up. Controlled ventilation keeps the air healthy and dry.
Other Construction Studies topics
- Health & safety
- House design & room layout
- Insulation & energy upgrades
- Low-energy & eco-friendly design
- Timber, joints, tools & finishes
- U-values & heat-loss costs
- Water supply & plumbing
- Foundations & concrete
- Passive House & EnerPHit
- Vernacular & heritage buildings
- Windows & glazing
- Renewable energy systems
- Drainage & wastewater treatment
- External walls
- Pitched roofs
- Plaster, paint & floor finishes
- Stairs & landings
- Doors & thresholds
- Orientation, solar gain & shading
- Stud partitions & internal walls
- Universal design & lifetime use
- Central heating systems
- Ground floors & radon
- Site selection & layout
- Thermal bridges & condensation
- Timber upper floors
- Chimneys & flues
- Daylight & artificial lighting
- Electrical installation
- Flat roofs
- Planning permission & regulations
- House purchase & the industry